 MS5540B (RoHS*)
MINIATURE BAROMETER MODULE
* 10 - 1100 mbar absolute pressure range * 6 coefficients for software compensation stored on-chip * Piezoresistive silicon micromachined sensor * Integrated miniature pressure sensor 6.2 x 6.4 mm * 15 Bit ADC * 3-wire serial interface * 1 system clock line (32.768 kHz) * Low voltage and low power consumption * RoHS-compatible & Pb-free* DESCRIPTION
The MS5540B is a SMD-hybrid device including a precision piezoresistive pressure sensor and an ADCInterface IC. It is a miniature version of the MS5534B barometer/altimeter module and provides a 16 Bit data word from a pressure and temperature dependent voltage. MS5540B is a low power, low voltage device with automatic power down (ON/OFF) switching. A 3-wire interface is used for all communications with a microcontroller. Compared to MS5534A the pressure range (measurement down to 10 mbar) has been improved. Other improvements concern the ESD sensitivity, current consumption and converter accuracy. The MS5540B is fully software compatible to the MS5534A and MS5534B. In addition, the MS5540B is from its outer dimensions compatible to the MS54XX series of pressure sensors. The gel protection of the sensor provides a water protection sufficient for 100 m waterproof watches without any additional protection.
FEATURES
* * * * * * Resolution 0.1 mbar Supply voltage 2.2 V to 3.6 V Low supply current < 5 uA Standby current < 0.1 uA -40 to +85 operation temperature C C No external components required
APPLICATIONS
* * * * Mobile altimeter/barometer systems Weather control systems Adventure or multi-mode watches GPS receivers
BLOCK DIAGRAM
VDD MCLK Digital Interface ADC dig. Filter
Input MUX SENSOR +IN
DIN DOUT SCLK
-IN
Sensor Interface IC
SGND
Memory (PROM) 64 bits
GND
Fig. 1: Block diagram 5540B.
The European RoHS directive 2002/95/EC (Restriction of the use of certain Hazardous Substances in electrical and electronic equipment) bans the use of lead, mercury, cadmium, hexavalent chromium and polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).
*
DA5540B_007
00005540767 ECN 865
September 25th, 2006
1
PIN CONFIGURATION
Fig. 2: Pin configuration of MS5540B. Pin Name SCLK VSS PV (1) PEN (1) VDD MCL DIN DOUT Pin 1 2 3 4 5 6 7 8 Type I G N I P I I O Function Serial data clock Ground Negative programming voltage Programming enable Positive supply voltage Master clock (32.768 kHz) Serial data input Serial data output
NOTE 1) Pin 3 (PV) and PIN 4 (PEN) are only used by the manufacturer for calibration purposes and should not be connected.
ABSOLUTE MAXIMUM RATINGS
Parameter Supply voltage Storage temperature Overpressure Symbol VDD TS P Conditions Ta = 25 C Ta = 25 C
o o
Min -0.3 -40
Max 4 +85 10
Unit V C bar
o
Notes 1 2
NOTES 1) Storage and operation in an environment of dry and non-corrosive gases. 2) The MS5540B is qualified referring to the ISO Standard 2281 and can withstand an absolute pressure of 11 bar in salt water or 100 m water respectively.
DA5540B_007
00005540767 ECN 865
September 25th, 2006
2
RECOMMENDED OPERATING CONDITIONS
(Ta = 25 VDD = 3.0 V unless noted otherwise) C,
Parameter Operating pressure range Supply voltage Supply current, average (1) during conversion (2) standby (no conversion) Current consumption into MCLK (3) Operating temperature range Conversion time External clock signal (4) Duty cycle of MCLK Serial data clock
Symbol p VDD Iavg Isc Iss
Conditions
Min. 10 2.2
Typ.
Max 1100
Unit mbar abs. V A mA A A C ms kHz % kHz
3.0 4 1
3.6
VDD = 3.0 V
0.1 0.5
MCLK = 32.768 kHz T tconv MCLK SCLK MCLK = 32.768 kHz 30.000 40/60 32.768 50/50 -40 +25
+85 35 35.000 60/40 500
NOTES 1) Under the assumption of one conversion every second. Conversion means either a pressure or a temperature measurement started by a command to the serial interface of MS5540B. 2) During conversion the sensor will be switched on and off in order to reduce power consumption; the total on time within a conversion is about 2 ms. 3) This value can be reduced by switching off MCLK while MS5540B is in standby mode. 4) It is strongly recommended that a crystal oscillator be used because the device is sensitive to clock jitter. A square-wave form of the clock signal is a must.
DA5540B_007
00005540767 ECN 865
September 25th, 2006
3
ELECTRICAL CHARACTERISTICS
DIGITAL INPUTS
(T = -40 .. 85 VDD = 2.2 V .. 3.6 V) C C,
Parameter Input High Voltage Input Low Voltage Signal Rise Time Signal Fall Time
Symbol VIH VIL tr tf
Conditions
Min 80% VDD 0% VDD
Typ
Max 100% VDD 20% VDD
Unit V V ns ns
200 200
DIGITAL OUTPUTS
(T = -40 .. 85 VDD = 2.2 V .. 3.6 V) C C,
Parameter Output High Voltage Output Low Voltage Signal Rise Time Signal Fall Time AD-CONVERTER
Symbol VOH VOL tr tf
Conditions Isource = 0.6 mA Isink = 0.6 mA
Min 75% VDD 0% VDD
Typ
Max 100% VDD 20% VDD
Unit V V ns ns
200 200
(T = -40 .. 85 VDD = 2.2 V .. 3.6 V) C C,
Parameter Resolution Linear Range Conversion Time INL
Symbol
Conditions
Min 0
Typ 15
Max 40000 35
Unit Bit LSB ms LSB
MCLK = 32.768 kHz Within linear range
-4
+4
DA5540B_007
00005540767 ECN 865
September 25th, 2006
4
PRESSURE OUTPUT CHARACTERISTICS
With the calibration data stored in the interface IC of the MS5540B the following characteristics can be achieved:
(VDD = 3.0 V unless noted otherwise)
Parameter Resolution Absolute Pressure Accuracy Relative Pressure Accuracy Error over Temperature
Conditions p = 750 .. 1100 mbar Ta = 25 C p = 750 .. 1100 mbar Ta = 25 C T = 0 .. +50 C p = 300 .. 1000 mbar T = -40 .. +85 C p = 300 .. 1000 mbar 12 months VDD = 2.2 .. 3.6 V p = const.
Min
Typ 0.1
Max
Unit mbar
Notes 1 2 3 4 4 5
-1.5 -0.5 -1 -1 -1 -1.6
+1.5 +0.5 +1 +3
mbar mbar mbar mbar mbar
Long-term Stability Maximum Error over Supply Voltage
+1.6
mbar
NOTES 1) A stable pressure reading of the given resolution requires taking the average of 2 to 4 subsequent pressure values due to noise of the ADC. 2) Maximum error of pressure reading over the pressure range. 3) Maximum error of pressure reading over the pressure range after offset adjustment at one pressure point. 4) With the second-order temperature compensation as described in Section "FUNCTION". See next section for typical operating curves. 5) The long-term stability is measured with non-soldered devices.
TEMPERATURE OUTPUT CHARACTERISTICS
This temperature information is not required for most applications, but it is necessary to allow for temperature compensation of the pressure output.
(VDD = 3.0 V unless noted otherwise)
Parameter Resolution Accuracy Maximum Error over Supply Voltage
Conditions T = 20 C T = -40 .. +85 C VDD = 2.2 .. 3.6 V
Min 0.005 -0.8
Typ
Max 0.015 0.8
Unit C C C
Notes
2 -0.2 + 0.2
1
C
NOTES 1) With the second-order temperature compensation as described in Section "FUNCTION". See next section for typical operating curves.
DA5540B_007
00005540767 ECN 865
September 25th, 2006
5
TYPICAL PERFORMANCE CURVES
ADC-value D1 vs Pressure (typical)
22000
20000
18000
ADC-value D1 (LSB)
16000
85 C
14000
25C
-40C
12000
10000
8000
6000 0 100 200 300 400 500 600 700 800 900 1000 1100
Pressure (mbar)
D2 vs Temperature (typical)
36000
34000
32000
30000
ADC-value D2 (LSB)
28000
26000
24000
22000
20000
18000
16000 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80
Temperature ( C)
Absolute Pressure Accuracy (typical)
4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 -0.5 -1.0 -1.5 -2.0 0 100 200 300 400 500 600 700 800 900 1000 1100
Pressure Error (mbar)
85C 60C 25C 0C -40C
Pressure (mbar)
DA5540B_007
00005540767 ECN 865
September 25th, 2006
6
Temperature Error Accuracy vs Temperature (typical)
2.5 2.0 1.5 1.0
Temperature Error ( C)
0.5 0.0 -0.5 -1.0 -1.5 -2.0 -2.5 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80
1100 mbar 600 mbar 100 mbar
Temperature ( C)
Pressure Error Accuracy vs Temperature (typical)
4.0 3.5 3.0 2.5 2.0
Pressure Error (mbar)
1.5 1.0 0.5 0.0 -0.5 -1.0 -1.5 -2.0 -2.5 -3.0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80
1100 mbar 600 mbar 100 mbar
Temperature (C)
DA5540B_007
00005540767 ECN 865
September 25th, 2006
7
Temperature Error vs Supply Voltage (typical)
0.20
0.15
0.10
0.05
Temperature Error ( C)
0.00
-0.05
85C 25C -40C
-0.10
-0.15
-0.20
-0.25
-0.30 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6
Supply Voltage (V)
Pressure Error vs Supply Voltage (typical)
0.8
0.6
0.4
0.2
Pressure Error (mbar)
0.0
-0.2
1100 mbar 700 mbar 100 mbar
-0.4
-0.6
-0.8
-1.0 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6
Supply Voltage (V)
DA5540B_007
00005540767 ECN 865
September 25th, 2006
8
FUNCTION
GENERAL The MS5540B consists of a piezoresistive sensor and a sensor interface IC. The main function of the MS5540B is to convert the uncompensated analogue output voltage from the piezoresistive pressure sensor to a 16-Bit digital value, as well as providing a 16-Bit digital value for the temperature of the sensor. * measured pressure (16-Bit) * measured temperature (16-Bit) "D1" "D2"
As the output voltage of a pressure sensor is strongly dependent on temperature and process tolerances, it is necessary to compensate for these effects. This compensation procedure must be performed by software using an external microcontroller.
D1 Pressure
Sensor
D2 Word1..4
Calculation in external microcontroller
Temperature re
For both pressure and temperature measurement the same ADC is used (sigma delta converter): * for the pressure measurement, the differential output voltage from the pressure sensor is converted * for the temperature measurement, the sensor bridge resistor is sensed and converted During both measurements the sensor will only be switched on for a very short time in order to reduce power consumption. As both, the bridge bias and the reference voltage for the ADC are derived from VDD, the digital output data is independent of the supply voltage. FACTORY CALIBRATION Every module is individually factory calibrated at two temperatures and two pressures. As a result, 6 coefficients necessary to compensate for process variations and temperature variations are calculated and stored in the 64Bit PROM of each module. These 64-Bit (partitioned into four words of 16-Bit) must be read by the microcontroller software and used in the program converting D1 and D2 into compensated pressure and temperature values. PRESSURE AND TEMPERATURE MEASUREMENT The sequence of reading pressure and temperature as well as of performing the software compensation is depicted in Fig. 3 and Fig. 5. First the Word1 to Word4 have to be read through the serial interface. This can be done once after reset of the microcontroller that interfaces to the MS5540B. Next the compensation coefficients C1 to C6 are extracted using Bit-wise logical- and shift-operations (refer to Fig. 4 for the Bit-pattern of Word1 to Word4). For the pressure measurement the microcontroller has to read the 16 Bit values for pressure (D1) and temperature (D2) via the serial interface in a loop (for instance every second). Then, the compensated pressure is calculated out of D1, D2 and C1 to C6 according to the algorithm in Fig. 3 (possibly using quadratic temperature compensation according to Fig. 5). All calculations can be performed with signed 16-Bit variables. Results of multiplications may be up to 32-Bit long (+sign). In the flow according to Fig. 3 each multiplication is followed by a division. This division can be performed by Bit-wise shifting (divisors are to the power of 2). It is ensured that the results of these divisions are less than 65536 (16-Bit). For the timing of signals to read out Word1 to Word4, D1, and D2 please refer to the paragraph "Serial Interface".
DA5540B_007
00005540767 ECN 865
September 25th, 2006
9
Start System initialisation Read calibration data (factory calibrated) from PROM of MS5540
Word1, Word2, Word3 and Word4 (4x16 Bit)
Basic equations:
Example:
Word1 = 46940 Word2 = 40217 Word3 = 25172 Word4 = 47212
Convert calibration data into coefficients: (see bit pattern of Word1-Word4)
C1: Pressure sensitivity C2: Pressure offset C3: Temperature coefficient of pressure sensitivity C4: Temperature coefficient of pressure offset C5: Reference Temperature C6: Temperature coefficient of the temperature (15 Bit) (12 Bit) (10 Bit) (10 Bit) (11 Bit) (6 Bit)
SENST1 OFFT1 TCS TCO Tref TEMPSENS
C1 = 23470 C2 = 1324 C3 = 737 C4 = 393 C5 = 628 C6 = 25
Pressure and temperature measurement
Read digital pressure value from MS5540
D1 (16 Bit)
D1 = 16460
Read digital temperature value from MS5540
D2 (16 Bit)
D2 = 27856 UT1 = 25248
Calculate calibration temperature
UT1 = 8*C5+20224
Calculate actual temperature
Difference between actual temperature and reference temperature:
dT(D2) = D2 - Tref TEMP(D2) = 20 +dT(D2)*TEMPSENS
dT
= 2608
dT = D2 - UT1
Actual temperature:
TEMP = 200 + dT*(C6+50)/2 (0.1C resolution)
10
TEMP = 391 = 39.1 C
Calculate temperature compensated pressure
Offset at actual temperature:
OFF(D2) = OFFT1+TCO*dT(D2) SENS(D2) = SENST1+TCS*dT(D2)
OFF = C2*4 + ((C4-512)*dT)/212
Sensitivity at actual temperature:
OFF
= 5220
SENS = 49923 X = 23093 = 9716 = 971.6 mbar
SENS = C1 + (C3*dT)/210 + 24576 X = (SENS * (D1-7168))/214 - OFF
Temperature compensated pressure:
P = X*10/25 + 250*10
(0.1 mbar resolution)
P(D1,D2) = D1*SENS(D2)-OFF(D2)
P
Display pressure and temperature value
Fig. 3: Flow chart for pressure and temperature reading and software compensation. NOTES 1) Readings of D2 can be done less frequently, but the display will be less stable in this case. 2) For a stable display of 0.1 mbar resolution, it is recommended to display the average of 8 subsequent pressure values.
DA5540B_007
00005540767 ECN 865
September 25th, 2006
10
C1 (15 Bit)
C5/I
1 Bit
Word1
DB14
DB13
DB12
DB11
DB10
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
DB10
C5/II (10 Bit) Word2
DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB5 DB4
C6 (6 Bit)
DB3 DB2 DB1 DB0
C4 (10 Bit) Word3
DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB11 DB10
C2/I (6 Bit)
DB9 DB8 DB7 DB6
C3 (10 Bit) Word4
DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB5 DB4
C2/II (6-Bit)
DB3 DB2 DB1 DB0
Fig. 4: Arrangement (Bit-pattern) of calibration data in Word1 to Word4.
SECOND-ORDER TEMPERATURE COMPENSATION In order to obtain best accuracy over the whole temperature range, it is recommended to compensate for the non-linearity of the output of the temperature sensor. This can be achieved by correcting the calculated temperature and pressure by a second order correction factor. The second-order factors are calculated as follows:
TEMP < 200
yes
200 TEMP 450
yes
TEMP > 450
yes
Low Temperatures
T2 = 11*(C6+24)*(200 - TEMP)*(200 - TEMP) / 220 P2 = 3 *T2 * (P - 3500)/214
No correction
T2 = 0 P2 = 0
High Temperatures
T2 = 3*(C6+24)*(450 - TEMP)*(450 - TEMP) / 220 P2 = T2 * (P - 10000)/213
Calculate pressure and temperature
TEMP = TEMP - T2 P = P - P2
Fig. 5: Flow chart for calculating the temperature and pressure to the optimum accuracy.
DA5540B_007
00005540767 ECN 865
September 25th, 2006
11
SERIAL INTERFACE
The MS5540B communicates with microprocessors and other digital systems via a 3-wire synchronous serial interface as shown in Fig. 1. The SCLK (Serial clock) signal initiates the communication and synchronises the data transfer with each Bit being sampled by the MS5540B on the rising edge of SCLK and each Bit being sent by the MS5540B on the rising edge of SCLK. The data should thus be sampled by the microcontroller on the falling edge of SCLK and sent to the MS5540B with the falling edge of SCLK. The SCLK-signal is generated by the microprocessor's system. The digital data provided by the MS5540B on the DOUT pin is either the conversion result or the software calibration data. In addition the signal DOUT (Data out) is also used to indicate the conversion status (conversion-ready signal, see below). The selection of the output data is done by sending the corresponding instruction on the pin DIN (Data input). Following is a list of possible output data instructions:
* * * * * * *
Conversion start for pressure measurement and ADC-data-out Conversion start for temperature measurement and ADC-data-out Calibration data read-out sequence for Word1 Calibration data read-out sequence for Word2 Calibration data read-out sequence for Word3 Calibration data read-out sequence for Word4 RESET sequence
"D1" "D2"
(Figure 6a) (Figure 6b) (Figure 6c) (Figure 6d) (Figure 6c) (Figure 6d) (Figure 6e)
Every communication starts with an instruction sequence at pin DIN. Fig. 6 shows the timing diagrams for the MS5540B. The device does not need a `Chip select' signal. Instead there is a START sequence (3-Bit high) before each SETUP sequence and STOP sequence (3-Bit low) after each SETUP sequence. The SETUP sequence consists in 4-Bit that select a reading of pressure, temperature or calibration data. In case of pressure(D1) or temperature- (D2) reading the module acknowledges the start of a conversion by a low to high transition at pin DOUT during the last bit of the STOP sequence. Two additional clocks at SCLK are required after the acknowledge signal. Then SCLK is to be held low by the microcontroller until a high to low transition on DOUT indicates the end of the conversion. This signal can be used to create an interrupt in the microcontroller. The microcontroller may now read out the 16-Bit word by giving another 17 clocks on the SLCK pin. It is possible to interrupt the data READOUT sequence with a hold of the SCLK signal. It is important to always read out the last conversion result before starting a new conversion. The RESET sequence is special as its unique pattern is recognised by the module in any state. By consequence it can be used to restart if synchronisation between the microcontroller and the MS5540B has been lost. This sequence is 21-Bit long. The DOUT signal might change during that sequence (see Fig. 6e). It is recommended to send the RESET sequence before each CONVERSION sequence to avoid hanging up the protocol permanently in case of electrical interference.
DOUT SCLK
Conversion start for pressure measurement and ADC-data-out "D1":
end of conversion
start of conversion
conversion (33ms)
ADC-data out MSB DB7 DB6 DB5 DB4 DB3 DB2 DB1
ADC-data out LSB DB0 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
DIN
sequence: START+P-measurement Bit0 Bit1 Bit2 Bit3 Bit4 Bit5 Bit6 Bit7 Bit8 Bit9 Start-bit Setup-bits Stop-bit
Fig. 6a: D1 ACQUISITION sequence.
DA5540B_007
00005540767 ECN 865
September 25th, 2006
12
DOUT SCLK
Conversion start for temperature measurement and ADC-data-out "D2":
end of conversion
start of conversion
conversion (33ms)
ADC-data out MSB DB7 DB6 DB5 DB4 DB3 DB2 DB1
ADC-data out LSB DB0 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
DIN
sequence: START+T-measurement Bit0 Bit1 Bit2 Bit3 Bit4 Bit5 Bit6 Bit7 Bit8 Bit9 Start-bit Setup-bits Stop-bit
Fig. 6b: D2 ACQUISITION sequence.
DOUT SCLK
Calibration data read out sequence for word 1/ word 3:
coefficient-data out MSB DB7 DB6 DB5 DB4 DB3 DB2 DB1 sequence: coefficient read + address Bit0 Bit1 Bit2 Start-bit Bit3 Bit4 Bit5 Bit6 Bit7 Bit8 Bit9 Bit10 Bit11 Setup-bits Stop-bit address word 1 address word 3
coefficient-data out LSB DB0 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
DIN
Fig. 6c: Word1, Word3 READING sequence.
DOUT SCLK
Calibration data read out sequence for word 2/ word 4:
coefficient-data out MSB DB7 DB6 DB5 DB4 DB3 DB2 DB1 sequence: coefficient read + address Bit0 Bit1 Bit2 Bit3 Bit4 Bit5 Bit6 Bit7 Bit8 Bit9 Bit10 Bit11 Start-bit Setup-bits Stop-bit address word 2 address word 4
coefficient-data out LSB DB0 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
DIN
Fig. 6d: W2, W4 READING sequence.
DIN
DOUT SCLK
RESET - sequence:
sequence: RESET Bit0 Bit1 Bit2 Bit3 Bit4 Bit5 Bit6 Bit7 Bit8 Bit9 Bit10 Bit11Bit12 Bit13 Bit14 Bit15 Bit16 Bit17 Bit18 Bit19 Bit20
Fig. 6e: RESET sequence (21-Bit).
DA5540B_007
00005540767 ECN 865
September 25th, 2006
13
APPLICATION INFORMATION
GENERAL
The advantage of combining a pressure sensor with a directly adapted integrated circuit is to save other external components and to achieve a very low power consumption. The main application field for this system includes portable devices with battery supply, but its high accuracy and resolution make it also suited for industrial and automotive applications. The possibility to compensate the sensor with a software allows the user to adapt it to his particular application. Communication between the MS5540B and the widely available microcontrollers is realised over an easy-to-use 3-wire serial interface. Customers may select which microcontroller system to be used, and there are no specific standard interface cells required, which may be of interest for specially designed 4 Bit-microcontroller applications.
CALIBRATION
The MS5540B is factory calibrated. The calibration data is stored inside the 64-Bit PROM memory.
SOLDERING
Please refer to the application note AN808 for all soldering issues.
HUMIDITY, WATER PROTECTION
The silicon pressure transducer and the bonding wires are protected by a anticorrosive and antimagnetic protection cap. The MS5540B carries a metal protection cap filled with silicone gel for enhanced protection against humidity. The properties of this gel ensure function of the sensor even when in direct water contact. This feature can be useful for waterproof watches or other applications, where direct water contact cannot be avoided. Nevertheless the user should avoid drying of hard materials like for example salt particles on the silicone gel surface. In this case it is better to rinse with clean water afterwards. Special care has to be taken to not mechanically damage the gel. Damaged gel could lead to air entrapment and consequently to unstable sensor signal, especially if the damage is close to the sensor surface. The metal protection cap is fabricated of special anticorrosive and antimagnetic stainless steel in order to avoid any corrosive battery effects inside the final product. The MS5540B is qualified referring to the ISO Standard 2281 and can withstand a pressure of 11 bar in salt water. The concentration of the see water used for the qualification is 41 g of see salt for 1 litre of DI water. For underwater operations as specified in ISO Standard 2281 it is important to seal the sensor with a rubber Oring around the metal cap. Any salt water coming to the contact side (ceramic and pads) of the sensor could lead to permanent damage. Especially for "water-resistant 100 m" watches it is recommended to provide a stable mechanical pusher from the backside of the sensor. Otherwise the overpressure might push the sensor backwards and even bend the electronic board on which the sensor is mounted.
LIGHT SENSITIVITY
The MS5540B is protected against sunlight by a layer of white gel. It is, however, important to note that the sensor may still be slightly sensitive to sunlight, especially to infrared light sources. This is due to the strong photo effect of silicon. As the effect is reversible there will be no damage, but the user has to take care that in the final product the sensor cannot be exposed to direct light during operation. This can be achieved for instance by placing mechanical parts with holes in such that light cannot pass.
CONNECTION TO PCB
The package outline of the module allows the use of a flexible PCB to connect it. This can be important for applications in watches and other special devices, and will also reduce mechanical stress on the device. For applications subjected to mechanical shock, it is recommended to enhance the mechanical reliability of the solder junctions by covering the rim or the corners of MS5540B' ceramic substrate with glue or Globtop-like s material.
DA5540B_007
00005540767 ECN 865
September 25th, 2006
14
DECOUPLING CAPACITOR
Particular care must be taken when connecting the device to power supply. A 47 F tantalum capacitor must be placed as close as possible of the MS5540B' VDD pin. This capacitor will stabilise the power supply during data s conversion and thus, provide the highest possible accuracy.
APPLICATION EXAMPLE: ALTIMETER SYSTEM USING MS5540B
MS5540B is a circuit that can be used in connection with a microcontroller in mobile altimeter applications. It is designed for low-voltage systems with a supply voltage of 3 V, particularly in battery applications. The MS5540B is optimised for low current consumption as the AD-converter clock (MCLK) can use the 32.768 kHz frequency of a standard watch crystal, which is supplied in most portable watch systems. For applications in altimeter systems Intersema can deliver a simple formula to calculate the altitude, based on a linear interpolation, where the number of interpolation points influences the accuracy of the formula.
3V-Battery
LCD-Display
VDD 32.768 kHz XTAL1
MS5540B
VDD MCLK DIN DOUT SCLK GND VSS 47uF Tantal XTAL2
Keypad 4/8bit-Microcontroller
EEPROM
optional
Figure 7: Demonstration of MS5540B in a mobile altimeter.
RECOMMENDED PAD LAYOUT
Pad layout for bottom side of MS5540B soldered onto printed circuit board
DA5540B_007
00005540767 ECN 865
September 25th, 2006
15
DEVICE PACKAGE OUTLINES
Fig. 8: Device package outlines of MS5540B.
DA5540B_007
00005540767 ECN 865
September 25th, 2006
16
ASSEMBLY
MECHANICAL STRESS
It is recommended to avoid mechanical stress on the PCB on which the sensor is mounted. The thickness of the PCB should be not below 1.6 mm. A thicker PCB is more stiff creating less stress on the soldering contacts. For applications where mechanical stress cannot be avoided (for example ultrasound welding of the case or thin PCB's in watches) please fix the sensor with drops of low stress epoxy (for example Hysol FP-4401).
MOUNTING
The MS5540B can be placed with automatic Pick&Place equipment using vacuum nozzles. It will not be damaged by the vacuum. Due to the low stress assembly the sensor does not show pressure hysteresis effects. Special care has to be taken to not touch the protective gel of the sensor during the assembly. It is important to solder all contact pads. The Pins PEN and PV shall be left open or connected to VDD. Do not connect the Pins PEN and PV to GND!
SEALING WITH O-RING
In products like outdoor watches the electronics must be protected against direct water or humidity. For those products the MS5540B provides the possibility to seal with an O-ring. The protective cap of the MS5540B is made of special anticorrosive and antimagnetic stainless steel with a polished surface. In addition to this the MS5540B is filled with silicone gel covering the sensor and the bonding wires. The O-ring (or O-rings) shall be placed at the outer diameter of the metal cap. This method avoids mechanical stress because the sensor can move in vertical direction.
CLEANING
The MS5540B has been manufactured under cleanroom conditions. Each device has been inspected for the homogeneity and the cleanness of the silicone gel. It is therefore recommended to assemble the sensor under class 10'000 or better conditions. Should this not be possible, it is recommended to protect the sensor opening during assembly from entering particles and dust. To avoid cleaning of the PCB, solder paste of type "no-clean" shall be used. Cleaning might damage the sensor!
ESD PRECAUTIONS
The electrical contacts except programming pads are protected against ESD according to 2 kV HBM (human body model). The PV programming pad is more sensitive due to the nature of the OTP programming cells that store the calibration coefficients. The breakdown voltage of PV is 1 kV. It is therefore essential to ground machines and personal properly during assembly and handling of the device. The MS5540B is shipped in antistatic transport boxes. Any test adapters or production transport boxes used during the assembly of the sensor shall be of an equivalent antistatic material.
DA5540B_007
00005540767 ECN 865
September 25th, 2006
17
ORDERING INFORMATION
Product Code
MS5540-BM
Product
Miniature Barometer Module with metal cap
Art.-Nr.
Package
SMD hybrid with solder paste, anticorrosive and antimagnetic metal protection cap, silicon gel sensor protection
Comments
Recommended for outdoor products
325540001
FACTORY CONTACTS
Intersema Sensoric SA Ch. Chapons-des-Pres 11 CH-2022 BEVAIX SWITZERLAND Tel. 032 847 9550 Tel. Int. +41 32 847 9550 Telefax +41 32 847 9569 e-mail: http://www.intersema.ch
NOTICE Intersema reserves the right to make changes to the products contained in this data sheet in order to improve the design or performance and to supply the best possible products. Intersema assumes no responsibility for the use of any circuits shown in this data sheet, conveys no license under any patent or other rights unless otherwise specified in this data sheet, and makes no claim that the circuits are free from patent infringement. Applications for any devices shown in this data sheet are for illustration only and Intersema makes no claim or warranty that such applications will be suitable for the use specified without further testing or modification.
DA5540B_007
00005540767 ECN 865
September 25th, 2006
18


▲Up To Search▲   

 
Price & Availability of MS5540-BM

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X